angle measurement
higher measurement accuracy
limit frequency 1kHz
with key
NEW! With base
NEW! Mounting adapter
measuring ranges
0.02 Nm up to 20,000 Nm
measurement accuracy
DRVL: ≤ 0.15% FS
optional ≤ 0.1% FS
DRVL-I up to VI: ≤ 0.1% FS
optional ≤ 0.05% FS
output signal
±10 V
10 ± 5 kHz
- voltage and frequency output
- advanced electromagnetic compatibility (EMC)
- adjustable output level for
rpm and angle signal (5 - 24 V) - higher rpm range for rpm- and angle measurements
measuring ranges
0.5 Nm up to 1000 Nm
measurement accuracy
≤ 0.25% FS
output signal
±5 V
10 ± 8 mA
- contactless signal transfer
- universally applicable
- versatile mounting options
measuring ranges
0,5 Nm up to 1000 Nm
measurement accuracy
≤ 0,5% FS
output signal
±5 V / 10 ± 8 mA
- Low cost
- Very short
- Broad input voltage range
- Current output and voltage output
- Optional rpm measurement
- Measurement accuracy: ≤ 0,5% of full scale
measuring ranges
0,5 Nm up to 1000 Nm
measurement accuracy
≤ 0,5% FS
output signal
±5 V / 10 ± 8 mA
→ as at DRBK
Extra features:
- Simultaneous rpm/torque indication
- display;
- rpm indication updated 1x sample/second;
- Torque updated 1000 samples/second
rpm
measuring ranges
0,5 Nm up to 5000 Nm
measurement accuracy
≤ 0,1% FS
output signal
±10 V
- 2 torque ranges
- integral signal amplifier
- low moment of inertia
- single supply voltage
- wide range of applications
- universally applicable
rpm
measuring ranges
0,1 Nm up to 15000 Nm
measurement accuracy
≤ 0,1% FS
output signal
±10 V
- waterproof (IP 67)
- contactless
- integral torque amplifier
- single supply voltage
- wide range of application
measuring ranges
1 Nm up to 10.000 Nm
measurement accuracy
≤ 0,15% FS
output signal
±5 V
- Square drive
- No service needed because of contactless data aquisition
- High interference immunity due to amplified active signal
- High accuracy due to frequency modulation and strain gage technology.
measuring ranges
1 Nm up to 20 Nm
measurement accuracy
≤ 0,15% FS
output signal
±5 V
- Hexagonal drive
- No service needed because of contactless data aquisition
- High interference immunity due to amplified active signal
- High accuracy due to frequency modulation and strain gage technology.
measuring ranges
1 Nm up to 20 Nm
measurement accuracy
≤ 0,15% FS
output signal
±5 V
- Hexagonal drive and rotation angle detection
- No service needed because of contactless data acquisition
- High accuracy due to frequency modulation and strain gage technology
- High interference rejection because of amplified active signal.
measuring ranges
2 Nm up to 20 Nm
measurement accuracy
≤ 0,15% FS
output signal
±5 V
- Quick-release coupling
- Short form, especially suitable for automatic screwing machines
- measurement, adjustment and examination without removing the screwing tool
- Suitable for permanent use
- Suitable for clockwise and counter-clockwise measurement
DRFDS (hex)
measuring ranges
0,5 Nm up to 5 Nm
measurement accuracy
≤ 0,25% FS
output signal
8 ± 2 kHZ
- High accuracy due to frequency modulation and strain gage technology
- Low power consumption
- High noise immunity due to digital signal
- Very compact design
DRDMS
DRDMN
measuring ranges
0,5 Nm up to 50 Nm
measurement accuracy
≤ 0,15% FS
output signal
±10 V
- Special sensors for planetary gears
- for mechanical connection to Maxon gearboxes
- with contactless data acquisition
- as a complete drive and torque measuring unit
- Test bench construction
- Screwing technology
Measuring range
1800Nm
Measurement accuracy
≤ ±0,2 % FS
Output signal
±10 V / 10 ± 5 kHZ
- PTO drive
- Voltage and frequency output
- Sturdy design
- Protection class IP67