NEW! Option "base"
NEW! Option mounting adapter
measuring ranges
0,02 Nm up to 20.000 Nm
measurement accuracy
DRVL: ≤0,15% (opt. ≤0,1%) F.S.
DRVL-I up to VI: ≤0,1% (opt. ≤0,05%) F.S.
output signal
±10 V / 10 ± 5 kHZ
- Voltage and frequency output
- Advanced electromagnetic compatibility (EMC)
- adjustable output level for speed- and angle signal (5 - 24 V)
- larger speed range for speed- and angle measurements
- optional 0,05% linearity error
NEW! Option "Mounting base"
NEW! Option "Mounting adapter"
measuring ranges
0,5Nm up to 1000Nm
measurement accuracy
≤ ±0,25 % F.S.
output signal
±5V / 10 ±8mA
measuring ranges
0,5 Nm up to 1000 Nm
measurement accuracy
≤ 0,5% F.S.
output signal
±5 V / 10 ± 8 mA
- Low cost
- Very short
- Broad input voltage range
- Current output and voltage output
- Optional speed measurement
- Measurement accuracy: ≤ 0,5% of full scale
measuring ranges
0,5 Nm up to 1000 Nm
measurement accuracy
≤ 0,5% F.S.
output signal
±5 V / 10 ± 8 mA
→ as at DRBK
Extra features:
- Simultaneous speed/torque indication
- display;
- Speed indication updated 1x sample/second;
- Torque updated 1000 samples/second
speed
measuring ranges
0,5 Nm up to 5000 Nm
measurement accuracy
≤ 0,1% F.S.
output signal
±10 V
- 2 torque ranges
- integral signal amplifier
- low moment of inertia
- single supply voltage
- wide range of applications
- universally applicable
speed
measuring ranges
0,1 Nm up to 15000 Nm
measurement accuracy
≤ 0,1% F.S.
output signal
±10 V
- waterproof (IP 67)
- contactless
- integral torque amplifier
- single supply voltage
- wide range of application
measuring ranges
1 Nm up to 10.000 Nm
measurement accuracy
≤ 0,15% F.S.
output signal
±5 V
- Square drive
- No service needed because of contactless data aquisition
- High interference immunity due to amplified active signal
- High accuracy due to frequency modulation and strain gage technology.
measuring ranges
1 Nm up to 20 Nm
measurement accuracy
≤ 0,15% F.S.
output signal
±5 V
- Hexagonal drive
- No service needed because of contactless data aquisition
- High interference immunity due to amplified active signal
- High accuracy due to frequency modulation and strain gage technology.
measuring ranges
1 Nm up to 20 Nm
measurement accuracy
≤ 0,15% F.S.
output signal
±5 V
- Hexagonal drive and rotation angle detection
- No service needed because of contactless data acquisition
- High accuracy due to frequency modulation and strain gage technology
- High interference rejection because of amplified active signal.
measuring ranges
2 Nm up to 20 Nm
measurement accuracy
≤ 0,15% F.S.
output signal
±5 V
- Quick-release coupling
- Short form, especially suitable for automatic screwing machines
- measurement, adjustment and examination without removing the screwing tool
- Suitable for permanent use
- Suitable for clockwise and counter-clockwise measurement
DRFDS (hex)
measuring ranges
0,5 Nm up to 5 Nm
measurement accuracy
≤ 0,25% F.S.
output signal
8 ± 2 kHZ
- High accuracy due to frequency modulation and strain gage technology
- Low power consumption
- High noise immunity due to digital signal
- Very compact design
DRDMS
DRDMN
measuring ranges
0,5 Nm up to 50 Nm
measurement accuracy
≤ 0,15% F.S.
output signal
±10 V
- Special sensors for planetary gears
- for mechanical connection to Maxon gearboxes
- with contactless data acquisition
- as a complete drive and torque measuring unit
- Test bench construction
- Screwing technology
Measuring range
1800Nm
Measurement accuracy
≤ ±0,2 % F.S.
Output signal
±10 V / 10 ± 5 kHZ
- PTO drive
- Voltage and frequency output
- Sturdy design
- Protection class IP67