Reaction torque transducer
"DRT"
for static applications
active and passive - execution
optional with bracket
Torque range from ± 0 - 2 Nm to ± 0 - 6000 Nm
-
Suitable for
- Testing pulsed tools.
- Torque wrenches.
- Electric screwdrivers

-
Features:
- Pulse screwdriver suitable.
- Lateral load insensitive.
- Permanently mountable.
- Exchangeable adapters integrated.
- Chip for sensor detection in connection with evaluation device GMV2.
Description:
This transducer was developed for static testing of pulsed tools, torque wrenches, electric screwdrivers, etc. In combination with the universal torque meter GMV2 a torque wrench can be tested without falsifying the result by excessively tightening the wrench.
The transducer can be mounted in any position with the help of the flange bracket to suit the tool to be tested. A variety of adapters are available for accepting the tool so that the tool can be tested with or without a socket. The device shaft is fitted with strain gages. It is not impacted by lateral loading because of the arrangement of the strain gages and an additional ball bearing.

Technical specifications | ||
Model | (a)ctive | (p)assive |
16 Measurement range (0 - ... Nm) |
DRT1 | 2 | 5 | 10 | 12 | 20 | DRT2 | 50 | 100 | 200 | 300 | DRT3 | 500 | 1000 | 2000 | 3000 | DRT4 | 4000 | 5000 | 6000 | |
|
Supply voltage | 12 V DC ± 10 % | 12 V max. |
Power consumption | approx. 30 mA | 35 mA max. |
Voltage output | 0- ± 5 V | 1 mV/V |
Nonlinerarity | < 0,1 % | |
Hysteresis | < 0,1 % | |
Deviation at zero point | ≤ ± 100 mV | ≤ ± 0,01 mV/V |
Internal resistance | -- | 350 Ω nominal |
Compensated temperature range | 5 - 45 °C | |
Operating temperature | 0 - 60 °C | |
Temperature fault Zero point Sensitivity |
0,01 % / K 0,02 % / K |
|
Mechanical overload | DRT1 + DRT2 100 %
DRT3 + DRT4 50 % |
Available connectors |
• Hexagonal connector: SW 5,5 till SW13 DIN ISO 272 |
Works certificate with 25% steps with right load.
Other calibrations upon request.
Accessories |
• Supply and display unit ![]() ![]() ![]() ValueMasterBase GMV2 ValueView |
![]() • Cables • Gland-Simulators • Mounting bracket |